Yes. Georgia allows dental assistants to place and expose radiographs under the direct supervision of a licensed dentist after completing the training required by the state's X-ray rule. That rule requires at least six hours of instruction for X-ray operators, started within 30 days of employment and finished within 90 days, with a training record kept for each operator.
What the Board of Dentistry allows
Georgia Board of Dentistry rule 150-9-.01(3)(b) lets a dental assistant "place and expose radiographs after completing the training required by" the state's rule on X-rays in the healing arts.
This is a direct supervision duty. A Georgia-licensed dentist must be in the office, personally diagnose and approve the procedure, stay on site while it is done and check the work before the patient leaves (150-9-.01(2)).
The six-hour operator training
Ga. Comp. R. & Regs. 111-8-90-.04(2)(a) requires the registrant to make sure X-ray machines are operated only by individuals instructed in safe operating procedures, with "at a minimum, six hours of instruction" in four areas:
- Protection against radiation: protective clothing, patient holding, time, distance and shielding, and radiation protection standards.
- Darkroom techniques: developing chemicals, film protection, cassettes and screens.
- Patient protection: beam limitation, setting techniques and biological effects of radiation.
- Machine safety: machine functions, safety procedures and recognizing problems.
Timing and records
Instruction must begin within 30 days after employment and be completed no later than 90 days after employment. The registrant keeps a record of all training for each operator, available to the state. A person with written proof of prior instruction is considered to meet the requirement.
The rule text we read does not name approved providers and does not set a refresher interval. Rules checked November 11, 2026.
Common mistakes
- Letting a new assistant expose radiographs before training is complete.
- Missing the 90-day deadline for completing the six hours.
- Keeping no written record of who taught what, and for how long.
- Using a handheld intraoral unit without checking the state X-ray rule. Rule 111-8-90-.04 says neither the tube housing nor the position indicating device may be hand-held during an exposure, so offices using handheld units should confirm with the Department of Public Health X-ray program how that applies.
Where our training fits
Our Radiation Safety for Dental Offices course is awareness and refresher training for the whole dental team: patient dose, image selection, collimation, receptors, handheld units, dosimetry, pregnancy, incidents and records. It is online, has no hands-on laboratory or clinical radiographs, and is not a license, permit, certification or accredited continuing education. We did not build it to Georgia's four-topic list (for example, it does not teach darkroom techniques in depth), and we do not claim it alone meets the six-hour requirement. The registrant decides what instruction meets the rule; ask the state if unsure.
What to do
- Set a 30-day start and 90-day finish date for each new operator's training.
- Make sure the six hours cover all four topic areas in the rule.
- Keep a written training record for each operator, and copies of any prior-training proof.
- Have a dentist present and supervising whenever an assistant exposes radiographs.
Training that helps
Radiation Safety for Dental Offices
For the whole dental team: justified images, rectangular collimation that cuts dose, handheld, panoramic and CBCT units, protected staff and inspection-ready records.
Sources
- Georgia Board of Dentistry, Chapter 150-9 Delegated duties (checked November 11, 2026)
- Ga. Comp. R. & Regs. 111-8-90-.04, X-rays in the healing arts (unofficial copy) (checked November 11, 2026)
Last reviewed November 11, 2026
This page is general information, not legal advice. Rules change; check the cited source or your state agency.