Yes, with training. Michigan's Board of Dentistry rules let a dentist assign the operation of dental radiographic equipment to an unlicensed dental assistant, a registered dental assistant or a registered dental hygienist. An unlicensed dental assistant must first successfully complete a course in dental radiography that is substantially equivalent to the course taught in board-approved programs.
What the rule allows
Table 1 in Michigan Administrative Code R 338.11411 lists "Operating of dental radiographic equipment" as a duty that may be done under assignment by an unlicensed dental assistant (UDA), a registered dental assistant (RDA) or a registered dental hygienist (RDH). The rule adds that a dentist may delegate necessary radiographs for a new patient to a UDA, RDA or RDH.
Under R 338.11401, assignment means the dentist designates a patient of record and describes the procedures to be performed. The dentist does not have to be in the office while assigned procedures are done.
Training for unlicensed assistants
Before operating radiographic equipment, a UDA "shall successfully complete a course in dental radiography that is substantially equivalent" to the course taught in board-approved programs. The rule points to R 338.11302, R 338.11303 and R 338.11307 for those programs.
A separate duty, inspecting and charting the mouth using a mirror and radiographs, needs direct supervision for a UDA and in-person or virtual training with performance evaluations.
Rules effective October 2, 2023; checked November 11, 2026.
What to keep on file
- Proof that each UDA completed a dental radiography course, with the course content and hours, so you can show it is substantially equivalent.
- Records showing which staff are RDAs or RDHs.
Common mistakes
- Assuming any short online course is "substantially equivalent" to a board-approved program course. Compare content and hours.
- Mixing up assignment and direct supervision duties in the table.
Where our training fits
Our Radiation Safety for Dental Offices course is awareness and refresher training for the whole dental team: patient dose, image selection, collimation, receptors, handheld units, dosimetry, pregnancy, incidents and records. It is online, has no hands-on laboratory or clinical radiographs, and is not a license, permit, certification or accredited continuing education. We do not claim it is substantially equivalent to a Michigan board-approved dental radiography course, and it should not be used as a UDA's qualifying course.
What to do
- Check that every UDA who takes X-rays has completed a qualifying dental radiography course.
- Keep the course certificate and outline in the personnel file.
- Use the R 338.11411 table to confirm the supervision level for each duty.
- Review the file when you hire and whenever duties change.
Training that helps
Radiation Safety for Dental Offices
For the whole dental team: justified images, rectangular collimation that cuts dose, handheld, panoramic and CBCT units, protected staff and inspection-ready records.
Sources
- Mich. Admin. Code R 338.11411 (unofficial copy) (checked November 11, 2026)
- Mich. Admin. Code R 338.11401 (unofficial copy) (checked November 11, 2026)
Last reviewed November 11, 2026
This page is general information, not legal advice. Rules change; check the cited source or your state agency.